Single-Use Portable Remote Racking Tools
Each CBS ArcSafe RRS-3 Single-Use Remote Racking System is a portable, standalone device designed to remotely rack a single type/style circuit breaker.
These inexpensive, single-application remote breaker racking systems allow the operator to use a hand-control unit to install and remove a breaker while standing up to 300 feet away.
RRS-3 units are most commonly assisted by strong magnets, meaning that no modifications are required to your switchgear. This also allows operators to easily move the RRS-3 from one breaker to another.
Each RRS-3 is custom built to interface with your specfic circuit breaker and is provided with a RSO-IV remote switch operator which is required for its operation. A radio remote control is also available.
Circuit Breaker Compatibility
The RRS-3 is compatible with the following circuit breaker models:
Model # | Manufacturer / Compatibility |
---|---|
RRS-3 3AF | Siemens-Allis, Siemens Type 3AF, 1200-3000 A (includes 5, 7, 15-3AF-250, 350, 500, 750, 1000) vacuum circuit breaker |
RRS-3 ABB-MB | ABB/BBC/ITE Type MB/MBE air circuit breakers |
RRS-3 ADVAC (CDL) | ABB Type ADVAC vacuum circuit breakers |
RRS-3 ADVAC (CDP) | ABB Type ADVAC vacuum circuit breakers |
RRS-3 AKD (ME) | General Electric (GE) AK-1-50 and AK-2-50 air circuit breakers |
RRS-3 AKD-5 | General Electric (GE) AK-2A-50, AK-2A-75, and AK-2A-100 air circuit breakers |
RRS-3 AKD-5 (S) | General Electric (GE) AK-2A, AK-3A, AK-15, and AK-25 air circuit breakers |
RRS-3 AKD-5(SE1) | General Electric (GE) AK-1-25 air circuit breaker |
RRS-3 AKD-6 | General Electric (GE) AKR air circuit breakers |
RRS-3 AKD-8 | General Electric (GE) AKD-8 air circuit breakers (AKR/AKRU-6D/10D-30/50) |
RRS-3 AKD-8 (L) | General Electric (GE) AKR-6D, AKR-10D, AKR-75, and AKR-100 air circuit breakers |
RRS-3 AKD-8 (S) | General Electric (GE) AKR-6D, AKR-10D, and AKR-30S air circuit breakers |
RRS-3 AKD-10 (L) | General Electric (GE) Wave Pro WPS/WPH/WPX 32/40/50 and EntelliGuard EGS/EGH/EGX 32/40/50 air circuit breakers |
RRS-3 AKD-10 (S) | General Electric (GE) Wave Pro WPS/WPH/WPX 08/16/20 and EntelliGuard EGS/EGH/EGX 08/16/20 air circuit breakers |
RRS-3 AMH | General Electric (GE) Type AMH-4.76-100/250/350-OD/1D air circuit breaker |
RRS-3 Compact NS | Merlin-Gerin, Schneider Type Compact NS (Electrically operated, housed within withdrawable circuit breaker chassis) molded case circuit breaker |
RRS-3 DB-50 | ![]() |
RRS-3 DB 75/100 | Westinghouse DB 75 and DB 100 air circuit breakers |
RRS-3 DH(L) | Westinghouse Type DH (includes 50DH150, 2000 A; 50DH250, 2000 A; 50DH350, 1200-3000 A; 75DH150, 600-1200 A; 75DH250, 1200-2000 A; 75DH500, 1200-2000 A; 150DH150, 600-1200 A; 150DH250, 1200-2000 A; 150DH500, 1200-2000 A; 150DH750, 1200-2000 A; 150DH1000, 1200-3000 A) air circuit breaker |
RRS-3 DH(S) | Westinghouse Type DH (includes 50DH150, 600-1200 A; 50DH250, 600-1200 A) air circuit breaker |
RRS-3 DHP, DVP (L) | Westinghouse Type DHP, DVP (includes 50DHP350, 3000 A; 750DHP500, 1200-3000 A; 150DHP500, 1200-3000 A; 150DHP750, 1200-3000 A; 150DHP1000, 1200-3000 A) air circuit breaker |
RRS-3 DHP/DVP (S) | Westinghouse Type DHP/DVP – 50DHP75, 1200 A; 50DHP250, 1200-2000 A; 50DHP350, 1200-2000 A air circuit breaker |
RRS-3 DS | Cutler-Hammer/Eaton/Square D/Westinghouse DS/DSL/DSII/DSLII 206/206S/416/416S/420/632/840 air circuit breakers |
RRS-3 Emax | ABB/Sace Emax E1-E6 air circuit breakers |
RRS-3 EntelliGuard G | General Electric Type EntelliGuard G air circuit breakers with ratings of 400–6000 A, including GG/GJ/GH/GK-04/07/08/10/13/16/20/25/32/40/50/64 |
RRS-3 FlashGard | Eaton FlashGard motor control center |
RRS-3 FPS, FMS | FPE Type FPS, FMS, 800-3200 A (includes FPS4, FPS5, FMS4, FMS5-30, 50, 75) air circuit breaker |
RRS-3 GMI | Siemens Type GMI, 1200-3000 A (includes 5-GMI, 7-GMI, 15-GMI) & Type 3AF, 1200-3000 A (includes 5-3AF, 7-3AF, 15-3AF) vacuum circuit breaker |
RRS-3 H/H-1 | Federal Pacific Electric (FPE) H/H-1 25, 50, 75, 100 H/H-1/HF/HF-1 air circuit breakers |
RRS-3 H-2/H-3 | Federal Pacific Equipment (FPE) H-2/HL-2 25, 35, 50, 65, 75, 100 H/HL-2 and H-3/HL-3 30, 42, 50, 65, 75, 100 H/HL-3 air circuit breakers |
RRS-3 HK | ![]() |
RRS-3 HK(S) | ABB/BBC/ITE Type HK, 1200-3000 A, 75-7250 MVA (includes 5 HK, 7.5 HK, 15 HK) air circuit breaker |
RRS-3 HK1000 | ABB/BBC/ITE Type HK, Type HK1000, 1200-3000 A, 1000 MVA (includes 15 HK, V HK) air circuit breaker |
RRS-3 HV | ITE Type HV air circuit breaker (5 kV, 600-1200 and 2000 A, 150-250 MVA) air circuit breaker |
RRS-3 HVF | Myers Power Product 1200–3000 A HVF-style vacuum circuit breakers |
RRS-3 KB/KC | ITE KB, KB-E, KB-G, KC, KC-E, and KC-G air circuit breakers |
RRS-3 KL (L) | ABB/BBC/ITE K-Line K-3000(S) and 4000(S) air circuit breakers |
RRS-3 KL (S) | ABB/BBC/ITE K-Line K-225(S), 600(S), 800(S), 1200(S), 1600(S), and 2000(S) air circuit breakers |
RRS-3 LA | Allis-Chalmers/Siemens-Allis LA/LAF1600/1600A/1600AF/1600B/2000/2000A air circuit breakers |
RRS-3 LA (L) | Allis-Chalmers/Siemens-Allis LA/LAF 3000/3000A/3200/3200A/4000/4000A/4000B/4000F air circuit breakers |
RRS-3 LA (S) | Allis-Chalmers/Siemens-Allis LA/LAF600/600A/600AF/600B/600F/800/800A/800B air circuit breakers |
RRS-3 LK | ABB/BBC/ITE LK/LKD/LKE 8/16/20/25/32/40/42 air circuit breakers |
RRS-3 MB | General Electric (GE) Type AM (includes AM - 4.16, 5, 7.2, 13.8, 15 with Clip In Elevating Motor) air circuit breaker |
RRS-3 MB II | ![]() ![]() ![]() |
RRS-3 MB, MBE | ABB, BBC, ITE Type MB, MBE (includes MB, MBE-8, 16, 20, 25, 32, 42) air circuit breaker |
RRS-3 MDS | Eaton/Cutler-Hammer MDS 08/16/20/30/32/40/50 air circuit breakers |
RRS-3 MDSR1 | Eaton/Cutler-Hammer Magnum DS, SB air circuit breakers, 800-4000 A, door closed |
RRS-3 MP, MC | Merlin-Gerin, Schneider Type Masterpact MP, MC, 800-6000 A (includes MP, MC 08, 12, 16, 20, 25, 30, 32, 40, 50, 63) air circuit breaker |
RRS-3 NT | Merlin Gerin/Schneider/Square D Masterpact NT 08/10/12/16 air circuit breakers |
RRS-3 NW | ![]() |
RRS-3 PBII | General Electric (GE) Type PowerBreak II 800, 1600, 2500, 3000, & 4000 A insulated case circuit breaker |
RRS-3 PB II(S) | General Electric (GE) PowerBreak II insulated case circuit breaker |
RRS-3 PowlVac | Powell Electrical Manufacturing PowlVac PV-style circuit breakers compatible with all standard PowlVac PV style circuit breakers with current ratings from 1200-3000A |
RRS-3 PowlVac (CDR) | Powell PowlVac vacuum circuit breakers with closing door racking (CDR) with ratings of 5 kV and 15 kV |
RRS-3 PDS | American Switchgear, McGraw-Edison switchgear PSD 5 kV, 150, 250 MVA, 1200 A air circuit breaker |
RRS-3 PSD (L) | American Switchgear, McGraw-Edison Type PSD (5 kV, 250 MVA, 2000 A & 15 kV, 250, 500 MVA, 1200, 2000 A) |
RRS-3 (S) | American Switchgear, McGraw-Edison Type PSD (5 kV, 150, 250 MVA, 1200 A) |
RRS-3 RL(L) | Siemens/Siemens-Allis RL/RLE/RLF3200/4000/5000 air circuit breakers |
RRS-3 RL(S) | Siemens/Siemens-Allis RL/RLE/RLF/RLI 800/1600/2000 air circuit breakers |
RRS-3 SecoVac (IEEE) | ![]() ![]() |
RRS-3 SecoVac (IEC) | General Electric (GE) Type SecoVac VB2+ (IEC breaker, switchgear only, Doop closed, includes 12-24 kV, 630-4000 A) |
RRS-3 Selpact | Merlin Gerin Selpact Air Circuit Breakers 1600/2000/2500/3200 A |
RRS-3 SPB (TTD-L) | Westinghouse, Cuter-Hammer, Eaton Type SPB (includes 2000 A - SPB-100; 2500 A - SPB-100; 3000 A - SPB-100) |
RRS-3 SPB (TTD-S) | Westinghouse, Cuter-Hammer, Eaton Type SPB (includes 250 A - SPB-50, SPB-65, SPB-100; 800 A - SPB-50, SPB-65, SPB-100; 1200 A - SPB-50, SPB-65, SPB-100; 1600 A - SPB-50, SPB-65, SPB-100; 2000 A - SPB-50, SPB-65, SPB-100) |
RRS-3 VB | ![]() |
RRS-3 VCP | Westinghouse VCP-style circuit breakers with current ratings of 1200A-3000A and voltage ratings of 5kV-15kV (includes 50VCP, 75VCP, and 150VCP) |
RRS-3 VCP-W(L) | Cutler-Hammer, Eaton, Westinghouse Type VCP-W, 1200-3000 A (includes 50VCP-W, 75VCP-W, 150VCP-W) vacuum circuit breaker |
RRS-3 VCP-W(S) | Cutler-Hammer, Eaton, Westinghouse Type VCP-W, 1200-3000 A (includes 50 VCP-W, 75VCP-W, 150 VCP-W) vacuum circuit breaker |
RRS-3 VH | General Electric (GE) Type VH vacuum circuit breaker |
RRS-3 Vmax | ABB Type Vmax, 600-2000 A (includes Vmax, L 12, 17; Vmax, W 12, 17) vacuum circuit breaker |
RRS-3 VR | ![]() |
RRS-3 WL | Siemens Type WL, 800-6000 A (includes WLS, WLL, WLC) air circuit breaker |
Radio Remote Pendant Station Specifications
CBS ArcSafe also offers a radio remote option that allows for operation up to 300 feet away without the need for an extension cable. The radio remote option also allows for closed-door racking to occur once the RRS-3 has been attached to the breaker.
- 2 control buttons
- Operating distance: 300 feet
- Frequency: 310-320 MHz
- Security coding: 128-bit framing protocol with 32-bit serial number embedded; error detection and correction encoded
- Environmental rating: IP65
- Temperature rating: -35° to 75° C (-31° to 167° F)
- TX size: 5.2″ x 1.75″ x 0.9″
- TX weight: 5 ounces
Remote Switch Operator
Model RRS-3 requires the RSO-IV to operate. All RRS-3 units come with the RSO-IV.
With the RSO-IV, a service technician can remotely operate on RRS-3 remote racking device for circuit breakers from a safe distance.
By allowing service personnel to stand outside the arc-flash boundary, the CBS ArcSafe RSO-IV for the RRS-3 reduces the need for a full-body arc flash hazard suit.
Some units will require the RSO-IV-NW; the RSO-IV-NW is an extension of the RSO-IV that allows the operator to operate interlocks.